Shipyards, suppliers and newbuilding news

R.W. Fernstrum Equipment

WEKA Boxcooler™

Uncoated 90/10 copper-nickel boxcooler mounted inside a sea chest — closed-circuit cooling for engines up to 10,000 kW with in-hull protection from ice, debris and grounding; built in the USA by R.W. Fernstrum under licence from WEKA Marine.

Description

The WEKA Boxcooler™ is a compact, closed-circuit cooling system mounted in a sea chest within the vessel's hull. R.W. Fernstrum & Company partners with WEKA Marine (Netherlands) to manufacture copper-nickel boxcoolers in the United States and supply the North and South American markets.

How it works

Engine coolant flows through a U-tube bundle suspended in the sea chest. Seawater warmed by the tubes rises, creating a natural convection flow that enters through inlet slots at the bottom of the sea chest and leaves through outlet slots near the top. Vessel motion adds forced circulation, so the cooler works both underway and alongside.

Advantages

  • Seawater never enters the hull; no raw-water pumps, strainers, filters, seacocks or seawater piping
  • Zero-discharge, low-maintenance solution — cools engines up to 10,000 kW
  • Mounted inside the hull: superior protection from ice, sand, debris and submerged obstacles
  • Removable bonnet — routine maintenance without dry-docking, with no seawater ingress
  • Uncoated 90/10 copper-nickel tubes — no coating and no ICAF (impressed-current anti-fouling) system required
  • Fully isolated from the hull; combined with the WEKA Protector Type T the copper-nickel keeps its natural anti-fouling layer
  • WEKA Guard protects the cooler from welding currents during construction

Configurations

  • Single or multiple heat sources (multiple circuits) on one unit
  • Stepped boxcoolers for tight spaces
  • Athwartship or longitudinal orientation
  • Top-down or bottom-mounted installation for repowers and added equipment

Applications

Propulsion and auxiliary engines, generator sets, reduction gears, bow thrusters, hydraulics, HVAC, compressors and electrical equipment on tugs, ferries, supply vessels, dredgers, fishing vessels, barges, cargo ships, carriers, tankers and icebreakers — the preferred choice for icy, sandy or debris-laden waters.

Service notes

Maximum test pressure 4.5 bar (65 psi). Replace the bonnet gasket whenever the bonnet is removed; replace the WEKA Protector every 5 years.

Specifications

TypeBoxcooler (in-hull sea-chest cooler, closed circuit)
Tube materialUncoated 90/10 copper-nickel
Cooling capacityEngines up to 10,000 kW
Max test pressure4.5 bar (65 psi)
Anti-foulingNatural Cu-Ni; no coating or ICAF required (with WEKA Protector Type T)
ConfigurationsSingle / multiple heat sources, stepped, athwartship or longitudinal, bottom mounted
MaintenanceRemovable bonnet in the water; no dry-docking
LicensorWEKA Marine B.V. (Netherlands)
Manufactured inMenominee, Michigan, USA

More from R.W. Fernstrum

All products of R.W. Fernstrum →